Most “something looks wrong” questions in HVAKR come down to a missing input rather than a calculation error. This section collects the most common ones, with the exact steps to resolve each.

  • Diagnostics: the in-app list of missing inputs and calculation problems, by workflow step. Start here when you are not sure which input causes a result.

  • Missing or Zero Loads: loads not generating, external loads absent, a space showing low loads because design conditions are missing, or infiltration lower than expected.

  • Unexpected Load Values: heating higher than cooling, peak cooling occurring late in the day, or outdoor air higher than a hand calculation.

  • Systems & Airflow: a negative Load-determined Supply, missing cooling-coil outputs, or an Average Space Setpoint reading N/A.

  • Weather & Reports: weather data not matching the project location, or an export stuck generating or showing Failed to generate.

A large share of load issues trace back to two inputs:

  1. Every space has a space type assigned. Space types carry internal loads, ventilation, and indoor design conditions. Without one, a space contributes no load.
  2. Envelope types have building data assigned. Wall, window, and roof types need an assembly selected before their loads appear.

If Diagnostics is available for your account, open it before you contact support. It often shows the missing input directly. See Diagnostics.

If a value still looks wrong after working through these pages, grant HVAKR Support access to the project so we can review the specific configuration.